ESA -62116 option for Anti-islanding Test

ESA -62116 option for Anti-islanding Test

The -62116 option of BriPower ESA series provides a perfect solution for anti-islanding test. ESA with -62116 options acts as power supply + electronic RLC load in this application.

Figure 1 Anti-islanding testing circuit (IEC62116-2008)

During the anti-island test, ESA-62116 simulates RLC load1, and meets test requirement of IEC62116-2008.

Figure 2 Operation Pane

In the test procedure of IEC62116-2008, there is no need to set R, L, C directly, all related settings are to set QL, PAC, QAC by adjusting R, L, C value. In ESA-62116 solution, user can set these parameters directly, and equivalent R, L, C values will be displayed.

Note: 1. ESA-62116 can only simulate RLC load for sine waveform, 50/60Hz input.

Leave A Reply